Astra 200 Multi-function Spirometer
Features & Specifications
The considerable strengths and benefits of our first class hardware and dazzling ComPAS Freedom™ software are available for ALL customers to utilize.
Beautifully designed final report presentations
Nothing compares to a ComPAS Freedom™ report!
Having completed tests with the Astra 200 Multi-function Spirometer using ComPAS Freedom™, the physician can be presented with a report suited to their requirements.
Reports can include the best results from patient efforts together with past test data from previous visits and a computer impression. The computer impression can be edited by the physician to conclude with a final clinical interpretation and electronic signature. If desired a summary of each test effort can be shown and also the quality assurance information.
In short the ComPAS Freedom™ reports are second to none and can be customized to be as simple or complex as the customer desires.
Astra 200 Multi-function Spirometer and ComPAS Freedom™
| |
|
|
 |
|
 |
Versatile Patient Entry and Recall |
|
Superb Flow Volume Testing |
| |
|
|
 |
|
 |
Precise Slow Vital Capacity |
|
Methocholine Challenge Testing |
| |
|
|
 |
|
 |
Extensive Manual Entry Options |
|
Informative and Detailed Help System |
| |
|
|
Cheerful support without voice mail
At Morgan Scientific, Inc. we have been servicing pulmonary function products for over 25 years in the United States. Our service engineers have a proud heritage of maintaining instruments for a far longer operational life than those of our competitors.
Service questions on both the hardware and software are usually resolved through telephone support. You do not have to sit through aggravating voice mail messages; our telephones are always answered by cheerful and helpful staff! When you call Morgan Scientific you will get a knowledgeable response.
Specifications
- FVC, FEV1, FEV6, FEV1/FVC, FEV1/FEV6, PEF
- Lung Age
- Direct in-office printing
- Print only the values you want
- Standard USB connectivity
- Optional Bluetooth-to-PC connectivity
- Reimbursable - View CPT-ICD9 Codes
- Unique flow triggers allow tidal breathing
- FVC, VC, MVV
- Quality assurance alerts
- Over 40 selectable parameters reported
- Selectable predicteds and interpretations
- Customized or pre-set program functions
Astra 200 Measured Parameters (Selectable):
- FVC - Forced Vital Capacity
- FEV1 : Forced Expiratory Volume in 1 second
- FEV1/FVC : Ratio of FEV1 to FVC
- FEV6 : Forced Expiratory Volume in 6 seconds
- FEV1/FEV6 : Ratio of FEV1 to FEV6
- FEV .5 : Forced Expiratory Volume in ,5 seconds
- FEV3 : Forced Expiratory Volume in 3 seconds
- FEV.5 / FVC : Ratio of FEV.5 to FVC
- FEV3 / FVC : Ratio of FEV3 to FVC
- FEV1 / VC : Ratio of FEV1 to Slow Vital Capacity
- FEF25% : Maximum Expiratory Flow @ 25% of blow
- FEF50% : Maximum Expiratory Flow @ 50% of blow
- FEF75% : Maximum Expiratory Flow @ 75% of blow
- FEF25%-75% : Avg. Forced Expiratory Flow between 25% and 75% of blow
- FEF75%-85% : Avg. Forced Expiratory Flow between 75% and 85% of blow
- FET25%-75% : Expiratory Time between 25% and 75% of blow
- FET 100%: Total forced expiratory time
- FEF50%/FIF50% : Maximum Expiratory Flow@50%/Mean Inspiratory Flow@50%
- FEV1 / FEV.5 : Forced Expiratory Volume @1 sec / Forced Expiratory Volume @ .5 sec
- FEV1 / PEF : Forced Expiratory Volume @1 sec / Peak Expiratory Flow
- FIF50% : Maximum Inspiratory Flow @ 50% of blow
- FIVC : Forced Inspiratory Vital Capacity
- FIV1 : Forced Inspiratory Volume in 1 second
- FIV1 / FVC : Ratio of FEV1 to FVC
- FEV1 / FIV1 : Ratio of FEV1 to FIV1
- PIF : Peak Inspiratory Flow
- MTT : Mean Transit Time
- PEF / PIF : Ratio of PEF to PIF
- BEV : Back:extrapolated Volume
- COPD Ind : COPD Index
- PEF : Peak Expiratory flow
- Lung Age
- MVV - Maximum Voluntary Ventilation
- Br/min : Breaths per minute
- VC - Slow Vital Capacity
- TV : Tidal Volume
- ERV : Expiratory Reserve Volume
- IRV : Inspiratory Reserve Volume
- IC : Inspiratory Capacity
- Ti : Inspiratory time
- Te : Expiratory time
- Tt : Total Time
- Ti/Tt : Ratio of Ti to Tt